冷却液
压水堆
腐蚀
放射分析
核工程
氢
材料科学
锕系元素
化学
放射化学
核化学
冶金
热力学
水溶液
物理化学
物理
有机化学
工程类
作者
Kuniki Hata,Satoshi Hanawa,Y. Chimi,Shunsuke Uchida,Derk H. Lister
标识
DOI:10.1080/00223131.2022.2127955
摘要
One of the major subjects for evaluating the corrosive conditions in the PWR primary coolant was to determine the optimal hydrogen concentration for mitigating PWSCC without any adverse effects on major structural materials. As suitable procedures for evaluating the corrosive conditions in PWR primary coolant, a couple of procedures, i.e. water radiolysis and ECP analyses, were proposed. The previous article showed the radiolysis calculation in the PWR primary coolant, which was followed by an ECP study here. The ECP analysis based on a couple of a mixed potential model and an oxide layer growth model was developed originally for BWR conditions, which was extended to PWR conditions with adding Li+ (Na+) and H+ effects on the anodic polarization curves. As a result of comparison of the calculated results with INCA in-pile-loop experiment data as well as other experimental data, it was confirmed that the ECPs calculated with the coupled analyses agreed with the measured within ±100 mV discrepancies.