抗坏血酸
微分脉冲伏安法
检出限
石墨烯
卟啉
化学
电化学
电子转移
电化学气体传感器
氧化还原
材料科学
循环伏安法
电极
无机化学
色谱法
光化学
纳米技术
物理化学
食品科学
作者
Li Wu,Lingyan Feng,Jinsong Ren,Xiaogang Qu
标识
DOI:10.1016/j.bios.2012.01.007
摘要
A new type of porphyrin-functionalized graphene was synthesized and used for highly selective and sensitive detection of dopamine (DA). The aromatic π–π stacking and electrostatic attraction between positively-charged dopamine and negatively-charged porphyrin-modified graphene can accelerate the electron transfer whereas weakening ascorbic acid (AA) and uric acid (UA) oxidation on the porphyrin-functionalized graphene-modified electrode. Differential pulse voltammetry was used for electrochemical detection, the separation of the oxidation peak potentials for AA-DA, DA-UA and UA-AA is about 188 mV, 144 mV and 332 mV, which allows selectively determining DA. The detection limit of DA can be as low as 0.01 μM. More importantly, the sensor we presented can detect DA in the presence of large excess of ascorbic acid and uric acid. With good sensitivity and selectivity, the present method was applied to the determination of DA in real hydrochloride injection sample, human urine and serum samples, respectively, and the results was satisfactory.
科研通智能强力驱动
Strongly Powered by AbleSci AI