摘要
In the cooling process of high-temperature calcined petroleum coke (CPC) inside a cooling water jacket, some problems such as uneven heat transfer, difficult heat conduction, and easy oxidation seriously affect the quality of CPC. Based on the computational fluid dynamics, this paper performed heat transfer analysis and numerical simulation for the cooling water jacket on both the water side and coke side, studied the evolutions of the internal temperature field, and obtained the nonuniform temperature field. Meanwhile, in order to enhance the heat transfer performance of the cooling water jacket, one modified measure was put forward by installing heat exchange tubes inside the cooling water jacket. The simulation results manifested that the modified measure of the cooling water jacket can enhance heat transfer performance significantly. Compared with the initial model, the outlet average temperature of CPC reduces by 293.89 K, and the cooling efficiency of the cooling water jacket enhances by 30.84%. Additionally, the temperature uniformity coefficient on the outlet cross section increases by 13.40%, which demonstrates that the modified structure has superior relative heat transfer performance.