Abstract Aims Contact force (CF)–sensing radiofrequency (RF) catheters with an ablation index have shown reproducible outcomes for the treatment of atrial fibrillation (AF) in large multicentre studies. A dual-energy (DE) focal CF catheter to deliver RF and unipolar/biphasic pulsed field ablation (PFA), integrated with a three-dimensional (3D) mapping system, can provide operators with additional flexibility. The SmartfIRE study assessed the safety and efficacy of this novel technology for the treatment of drug-refractory, symptomatic paroxysmal AF. Results at 3 months post-ablation are presented here. Methods and results Pulmonary vein isolation (PVI) was performed using a DE focal, irrigated CF-sensing catheter with the recommendation of PFA at posterior/inferior and RF ablation at the anterior/ridge/carina segments. Irrespective of energy, a tag size of 3 mm; an inter-tag distance ≤6 mm; a target index of 550 for anterior, roof, ridge, and carina; and a target index of 400 for posterior and inferior were recommended. Cavotricuspid isthmus ablation was permitted in patients with documented typical atrial flutter. The primary effectiveness endpoint was acute procedural success. The primary safety endpoint was the rate of primary adverse events (PAEs) within 7 days of the procedure. A prespecified patient subset underwent oesophageal endoscopy (EE; 72 h post-procedure), neurological assessment (NA; pre-procedure and discharge), and cardiac computed tomography (CT)/magnetic resonance angiogram (MRA) imaging (pre-procedure and 3 months post-procedure) for additional safety evaluation, and a mandatory remapping procedure (Day 75 ± 15) for PVI durability assessment. Of 149 patients enrolled between February and June 2023, 140 had the study catheter inserted (safety analysis set) and 137 had ablation energy delivered (per-protocol analysis set). The median (Q1/Q3) total procedure and fluoroscopy times were 108.0 (91.0/126.0) and 4.2 (2.3/7.7) min (n = 137). The acute procedural success rate was 100%. First-pass isolation was achieved in 89.1% of patients and 96.8% of veins. Cavotricuspid isthmus ablations were successfully performed in 12 patients [pulsed field (PF) only: 6, RF only: 5, and RF/PF: 1]. The PAE rate was 4.4% [6/137 patients; 2 pulmonary vein (PV) stenoses, 2 cardiac tamponades/perforations, 1 stroke, and 1 pericarditis]. No coronary artery spasm was reported. No oesophageal lesion was seen in the EE subset (0/31, 0%). In the NA subset (n = 30), microemboli lesions were identified in 2 patients (2/30, 6.7%), both of which were resolved at follow-up; only 1 was symptomatic (silent cerebral lesion, 3.3%). In the CT/MRA subset (n = 30), severe PV narrowing (of >70%) was detected in 2 patients (2/30, 6.7%; vein level 2/128, 1.6%), of whom 1 underwent dilatation and stenting and 1 was asymptomatic; both were associated with high index values and a small inter-tag distance. In the PV durability subset (n = 30), 100/115 treated PVs (87%) were durably isolated and 18/30 patients (60.0%) had all PVs durably isolated. Conclusion A DE focal CF catheter with 3D mapping integration showed a 100% acute success rate with an acceptable safety profile in the treatment of paroxysmal AF. Prespecified 3-month remapping showed notable PVI durability. Clinical trial registration ClinicalTrials.gov Identifier: NCT05752487.
最长约 10秒,即可获得该文献文件

科研通智能强力驱动
Strongly Powered by AbleSci AI
更新
PDF的下载单位、IP信息已删除 (2025-6-4)

科研通是完全免费的文献互助平台,具备全网最快的应助速度,最高的求助完成率。 对每一个文献求助,科研通都将尽心尽力,给求助人一个满意的交代。
实时播报
给鱼挠痒痒完成签到,获得积分10
1秒前
Camellia发布了新的文献求助10
1秒前
xxx发布了新的文献求助10
2秒前
Micros发布了新的文献求助10
2秒前
张光光完成签到,获得积分10
2秒前
瓜子发布了新的文献求助10
2秒前
友好从梦完成签到 ,获得积分10
3秒前
5秒前
6秒前
Fishball发布了新的文献求助10
6秒前
海带完成签到,获得积分10
7秒前
liu关注了科研通微信公众号
7秒前
8秒前
8秒前
8秒前
8秒前
Jasper应助AbeleChuang采纳,获得10
8秒前
9秒前
小石头完成签到,获得积分10
9秒前
9秒前
哟梦完成签到,获得积分10
9秒前
共享精神应助ikun采纳,获得10
10秒前
可爱的函函应助小黑哥采纳,获得10
11秒前
超级冬瓜完成签到,获得积分10
11秒前
水水发布了新的文献求助10
12秒前
12秒前
日升换月落完成签到 ,获得积分10
12秒前
112234发布了新的文献求助10
13秒前
weiwenzuo发布了新的文献求助80
13秒前
hyperthermal1完成签到,获得积分10
13秒前
14秒前
mima发布了新的文献求助10
14秒前
xxx完成签到,获得积分10
15秒前
16秒前
徐嘉雯发布了新的文献求助10
16秒前
16秒前
领导范儿应助yuanqi采纳,获得10
17秒前
17秒前
冷静小天鹅完成签到,获得积分10
17秒前
18秒前
高分求助中
传播真理奋斗不息——中共中央编译局成立50周年纪念文集 2000
The Oxford Encyclopedia of the History of Modern Psychology 2000
Chinesen in Europa – Europäer in China: Journalisten, Spione, Studenten 1200
Deutsche in China 1920-1950 1200
中共中央编译局成立四十周年纪念册 / 中共中央编译局建局四十周年纪念册 950
Applied Survey Data Analysis (第三版, 2025) 850
Mineral Deposits of Africa (1907-2023): Foundation for Future Exploration 800
热门求助领域 (近24小时)
化学 材料科学 医学 生物 工程类 有机化学 物理 生物化学 纳米技术 计算机科学 化学工程 内科学 复合材料 物理化学 电极 遗传学 量子力学 基因 冶金 催化作用
热门帖子
关注 科研通微信公众号,转发送积分 3876712
求助须知:如何正确求助?哪些是违规求助? 3419229
关于积分的说明 10712650
捐赠科研通 3143940
什么是DOI,文献DOI怎么找? 1734642
邀请新用户注册赠送积分活动 836959
科研通“疑难数据库(出版商)”最低求助积分说明 782884