底纹
雾
环境科学
城市热岛
相对湿度
微粒
环境工程
空气污染
小气候
沉积(地质)
热的
气溶胶
气象学
大气科学
冷凝
热舒适性
野外试验
空气质量指数
湿度
空气温度
太阳增益
污染
领域(数学)
作者
Feiyue Liu,Wei Ding,Yongjie Qi,Zejin Yang,Li Han
标识
DOI:10.1177/1420326x261436797
摘要
Summer urban air pollution and heat waves pose serious health risks. Although mist spraying is widely used to alleviate heat stress, its combined effects with different shading conditions on outdoor thermal-pollution environments remain unclear. This study aims to identify the optimal integrated misting-shading system by evaluating their ameliorating effects. Field experiments on a university campus in Xi'an involved five groups: “natural shading + no mist spraying” “natural shading + mist spraying”, “no shading + mist spraying”, “artificial shading + mist spraying” and “no shading + no mist spraying” (control). We continuously measured air temperature, relative humidity, particulate matter (PM) and O 3 concentrations. The Mann–Whitney U test compared regulatory effects, and particle size ratios (PM x /PM y , x < y ) analyzed condensation and deposition for PM 1 , PM 2.5 and PM 10 . Results show that “natural shading + mist spraying” achieved the most significant synergistic regulation, reducing air temperature by 12.6% and O 3 by 10.8%, while increasing relative humidity by 26.2%. “Artificial shading + mist spraying” most effectively promoted PM 2.5 condensation and deposition. Overall, this study offers a practical assessment of misting-shading systems to simultaneously alleviate heat and pollution, advancing integrated mitigation strategies and providing empirical evidence for climate-adaptive urban design.
科研通智能强力驱动
Strongly Powered by AbleSci AI