Evaluation the effect of breathing filters on end-tidal carbon dioxide during inferior abdominal surgery in infants and changes of tidal volume and respiratory rate needs for preventing of increasing end-tidal carbon dioxide
Background: The aim of this study was to prevent of increasing end-tidal carbon dioxide (ETCO 2) with changing of vital capacity and respiratory rate when using of birthing filter in infants. Materials and Methods: In a randomized clinical trial study, ninety-four infant’ patients were studied in three groups. Basic values, such as peak inspiratory pressure, tidal volume, minute ventilation, respiratory rate, and partial pressure of ET CO 2 (PETCO 2 ) level had been evaluated after intubation, 10 min after intubation and 10 min after filter insertion. In the first group, patients only observed for changing in ETCO 2 level. In the second and the third groups, respiratory rates and tidal volume had been increased retrospectively, until that ETCO 2 ≤35 mmHg was received. We used ANOVA, Chi-square, and descriptive tests for data analysis. P < 0.05 was considered statistically significant. Results: Tidal volume 10 min after filter insertion was statistically higher in Group 3 (145.0 ± 26.3 ml) versus 129.3 ± 38.9 ml in Group 1 and 118.7 ± 20.8 ml in Group 2 ( P = 0.02). Furthermore, respiratory rate at this time was statistically higher in Group 2 (25.82 ± 0.43) versus Groups 1 and 3 (21.05 ± 0.20 ml and 21.02 ± 0.60 ml, respectively) ( P = 0.001). Minute volume and PETCO 2 level were statistically significant between Group 1 and the other two groups after filter insertion ( P = 0.01 and P = 0.00,1 respectively). Conclusion: With changing the vital capacity and respiratory rate we can control PETCO 2 level ≤35 mmHg during using of birthing filters in infants. We recommend this instrument during anesthesia of infants.