This study proposes an innovative geothermal exploration system that combines an enhanced geothermal system (EGS) and a closed coaxial heat exchanger geothermal system (CCGS) for heat extraction in discrete fracture networks and coaxial wells. Firstly, a mathematical model was established, considering the fluid flow and heat transfer processes in fractures, reservoir matrix, and wellbores. Subsequently, an analysis was conducted to examine the temperature and velocity contours in discrete fracture networks and coaxial wells. Moreover, the heat extraction performance of the proposed EGS-CCGS was compared with that of a traditional EGS. Finally, the key factors affecting heat production were discussed and analyzed. The results showed that the CCGS can significantly enhance the heat extraction efficiency of fractured geothermal systems. When fracture connectivity is suboptimal, the heat extraction efficiency for the system can be improved by up to 150%. The optimal injection rates for the combined EGS-CCGS system are 120 kg/s for the EGS and 25 kg/s for the CCGS. When the fracture connectivity is low, the rock matrix thermal conductivity has a significant impact on heat extraction efficiency, while the fracture permeability has a relatively minor effect. Conversely, the opposite effects are reported when the fracture connectivity is high.