Expired nitrous oxide from patients in the recovery room is considered to be the major source of air pollution. We measured expired concentrations of nitrous oxide in three patients and three volunteers. After only 5 minute inhalation of 50% nitrous oxide, it took over 2 hours for exhaled N2O concentration to decrease to 25 ppm in volunteers and after 30 minute inhalation, it took over 4 hours. The patients inhaled 50% nitrous oxide for 60, 165, 150 minutes, respectively and all patients expired nitrous oxide, the concentrations of which exceed 100 ppm over 3 hours. As to the patient who inhaled nitrous oxide for 150 minutes, expired nitrous oxide over 25 ppm was detected 10 hours after the end of anesthesia, and it was 4 ppm even after 20 hours. Any personnel including anesthesiologists and nurses working in the operating room can be exposed to high concentrations of nitrous oxide exceeding the permissible limit of 25 ppm, whenever they take care closely of their patients. We do not have any effective measures to protect us from this kind of air pollution except employing total intravenous anesthesia.