扫描电子显微镜
临界尺寸
偏压
材料科学
硅
物理
分析化学(期刊)
光学
光电子学
化学
电压
量子力学
色谱法
作者
Chie Shishido,Maki Tanaka,Mayuka Osaki
摘要
The measurement accuracy of critical-dimension scanning electron microscopy (CD-SEM) at feature sizes of 10 nm and below is investigated and methods for improving accuracy and reducing CD bias (the difference between true and measured CD values) are proposed. Simulations indicate that CD bias varies with feature size (CD) when the electron scatter range exceeds the CD. As the change in the CD-SEM waveform with decreasing CD is non-uniform, the CD bias in the results is strongly dependent on the algorithm employed to process the CD-SEM data. Use of the threshold method with a threshold level equal to 50% (Th = 50%) is shown to be effective for suppressing the dependence of CD bias on CD. Through comparison of experimental CD-SEM measurements of silicon line patterns (7-40 nm) with atomic force microscopy (AFM) measurements, it is confirmed that the threshold method (Th = 50%) is a effective as predicted, affording a largely invariant CD bias. The model-based library (MBL) method, which is theoretically capable of eliminating CD bias, is demonstrated to reduce the CD bias to near-zero levels. These experiments demonstrate the feasibility of next-generation CD-SEM for the measurement of feature sizes of the order of 10 nm and smaller.
科研通智能强力驱动
Strongly Powered by AbleSci AI