剥落
偏转(物理)
预应力混凝土
耐火试验
结构工程
材料科学
混凝土保护层
钢筋混凝土
耐火性
复合材料
工程类
光学
物理
作者
Kai Yan,Jiacheng Yang,Jeung‐Hwan Doh,Xin Zhang
标识
DOI:10.1002/suco.201900359
摘要
Abstract This article presents the details of a fire test on eight prestressed reactive powder concrete (RPC) beams cured with 150°C hot air. The test specimens varied in load ratio, cover thickness of tendons, bonded and unbonded tendons, and partial prestressing ratio. The thermal fields, deflection behavior, effective prestress, fire endurance, failure modes, and crack patterns of the beams were observed and recorded, revealing that no obvious fire‐induced spalling occurred on the prestressed RPC beams. The fire test results indicate that the failure of prestressed RPC beams was driven by direct fire exposure and fracture of tendons and longitudinal rebars after generation of wide cracks in the beams. In extreme fire, prestressed RPC beams that were under‐reinforced at ambient temperature may fail as low‐reinforced beams. Fire resistance of the prestressed RPC beams dramatically improved with a decrease of load ratio and increase of cover thickness of tendons. Bonded prestressed RPC beams showed superior performance over equivalent unbonded prestressed RPC beams in fire. The whole‐scale transferring effect of prestress loss in unbonded beams should be considered for fire resistance performance design based on structural systems.