Pauli Kehayias,Edlyn V. Levine,Luca Basso,Jacob Henshaw,Maziar Saleh Ziabari,Michael Titze,Raymond A. Haltli,Jerry Okoro,D. R. Tibbetts,Darlene M. Udoni,Edward S. Bielejec,Michael P Lilly,Tzu‐Ming Lu,Peter D. D. Schwindt,Andrew M. Mounce
标识
DOI:10.1103/physrevapplied.17.014021
摘要
Quantum diamond microscope (QDM) magnetic field imaging is an emerging interrogation and diagnostic technique for integrated circuits (ICs). To date, the ICs measured with a QDM have been either too complex for us to predict the expected magnetic fields and benchmark the QDM performance or too simple to be relevant to the IC community. In this paper, we establish a 555 timer IC as a ``model system'' to optimize QDM measurement implementation, benchmark performance, and assess IC device functionality. To validate the magnetic field images taken with a QDM, we use a spice electronic circuit simulator and finite-element analysis (FEA) to model the magnetic fields from the 555 die for two functional states. We compare the advantages and the results of three IC-diamond measurement methods, confirm that the measured and simulated magnetic images are consistent, identify the magnetic signatures of current paths within the device, and discuss using this model system to advance QDM magnetic imaging as an IC diagnostic tool.