Coronary CT angiography using photon counting CT for the detection of coronary artery stenoses and coronary atherosclerotic plaque: comparison of reconstructions with 0.2 mm and 0.4 mm slice thickness

医学 冠状动脉造影 放射科 动脉 血管造影 冠状动脉疾病 冠状动脉粥样硬化 心脏病学 核医学 内科学 心肌梗塞
作者
T Zuhair Kassem,Stephan Achenbach,M Moshage,F Weidinger,Susanne Jung,S Smolka,M Marwan
出处
期刊:European Heart Journal [Oxford University Press]
卷期号:45 (Supplement_1)
标识
DOI:10.1093/eurheartj/ehae666.205
摘要

Abstract Photon Counting CT allows the acquisition of high-resolution data sets with 0.2 mm reconstructed slice thickness. It is unknown whether the detection of coronary artery stenoses, of coronary plaque or of vulnerable plaque characteristics is improved in data sets that employ maximum resolution. We therefore compared the identification of above characteristics in data sets reconstructed with 0.2 mm and 0.4 mm slice thickness In 30 patients with suspected coronary artery disease, sinus rhythm, a heart rate ≤65 beats/min, and body weight ≤ 100 kg, high-resolution data sets were acquired by photon counting CT (60 ml contrast i.v. at 6 ml/s) after s.c. application of nitrates in inspiratory breathhold. Data were reconstructed with 0.2 mm slice thickness at 0.1 mm increment and 0.4 mm slice thickness at 0.2 mm increment. Next to quantitative analysis of image quality parameters, all data sets were evaluated by two independent expert reviewers concerning subjective image quality as well as the ability to determine the presence of coronary artery stenoses, calcified and non- calcified plaque, as well as parameters of plaque vulnerability (positive remodeling, necrotic core, density < 30 HU and napkin-ring sign) using a 5-point Likert scale (-2 to +2) and a dedicated 11-segment coronary model. Of the 30 patients, 47% were male (mean age 58±12 years, mean heart rate 53±6 bpm, mean body weight 80±15 kg). The median dose length product was 508 mGy*cm. Mean image noise was 42±7 HU vs. 34±7 HU for 0.2 mm vs. 0.4 mm reconstructions (p < 0.001). The median image quality score was significantly higher for 0.2 mm reconstructions (3.8±0.8 vs 3.6±0.7). Of 335 coronary segments, none were classified as "unevaluable" while 87% vs. 76% were classified as "perfect" in 0.2 mm vs. 0.4 mm reconstructions (p < 0.001). Full confidence to rule-in or rule out significant coronary stenoses was achieved in 93% of segments in both reconstructions. The number of non-calcified plaques identified in 0.2 mm reconstructions was numerically higher than in 0.4 mm reconstructions (77 vs. 71, p = n.s.). On the Likert scale, the confidence to identify parameters of plaque vulnerability was significantly higher for 0.2 mm reconstructions (1.93 vs. 1.85, p < 0.001). In a selected patient group, photon counting CT coronary angiography demonstrated excellent image quality and an extremely low rate of unevaluable coronary segments. High-resolution reconstructions improve subjective image quality as was as the assessment of vulnerable plaque characteristics.

科研通智能强力驱动
Strongly Powered by AbleSci AI
科研通是完全免费的文献互助平台,具备全网最快的应助速度,最高的求助完成率。 对每一个文献求助,科研通都将尽心尽力,给求助人一个满意的交代。
实时播报
起起发布了新的文献求助10
3秒前
勤劳怜寒发布了新的文献求助20
4秒前
4秒前
4秒前
逸风望完成签到,获得积分10
5秒前
星辰大海应助lulu采纳,获得10
6秒前
7秒前
科研通AI5应助zhi采纳,获得10
9秒前
xxxxx完成签到,获得积分0
10秒前
Xueanliu发布了新的文献求助10
11秒前
16秒前
17秒前
赘婿应助Yi采纳,获得10
21秒前
lxw完成签到,获得积分10
21秒前
隐形曼青应助ZW采纳,获得10
22秒前
22秒前
23秒前
23秒前
打打应助健忘飞风采纳,获得10
24秒前
Xueanliu完成签到,获得积分20
24秒前
25秒前
科研通AI5应助淡定海亦采纳,获得30
26秒前
29秒前
29秒前
29秒前
李健的小迷弟应助章鱼采纳,获得10
30秒前
111发布了新的文献求助10
30秒前
31秒前
忧郁老默发布了新的文献求助10
31秒前
32秒前
32秒前
17完成签到,获得积分10
35秒前
符寄柔发布了新的文献求助10
36秒前
37秒前
健忘飞风发布了新的文献求助10
37秒前
高兴荔枝发布了新的文献求助10
37秒前
嗯哼发布了新的文献求助10
37秒前
淡定海亦发布了新的文献求助30
38秒前
完美世界应助GG小丁同学采纳,获得10
41秒前
dyem发布了新的文献求助10
41秒前
高分求助中
【此为提示信息,请勿应助】请按要求发布求助,避免被关 20000
ISCN 2024 – An International System for Human Cytogenomic Nomenclature (2024) 3000
Continuum Thermodynamics and Material Modelling 2000
Encyclopedia of Geology (2nd Edition) 2000
105th Edition CRC Handbook of Chemistry and Physics 1600
Maneuvering of a Damaged Navy Combatant 650
China—Art—Modernity: A Critical Introduction to Chinese Visual Expression from the Beginning of the Twentieth Century to the Present Day 360
热门求助领域 (近24小时)
化学 材料科学 医学 生物 工程类 有机化学 物理 生物化学 纳米技术 计算机科学 化学工程 内科学 复合材料 物理化学 电极 遗传学 量子力学 基因 冶金 催化作用
热门帖子
关注 科研通微信公众号,转发送积分 3776819
求助须知:如何正确求助?哪些是违规求助? 3322237
关于积分的说明 10209450
捐赠科研通 3037558
什么是DOI,文献DOI怎么找? 1666761
邀请新用户注册赠送积分活动 797656
科研通“疑难数据库(出版商)”最低求助积分说明 757976