陀螺仪
谐振器
材料科学
振动结构陀螺仪
噪音(视频)
微电子机械系统
光电子学
Q系数
光学
物理
计算机科学
量子力学
图像(数学)
人工智能
作者
Jae Yoong Cho,J.-K. Woo,Guohong He,Donguk Yang,Christopher Boyd,Sajal Singh,Ali Darvishian,Behrouz Shiari,Khalil Najafi
标识
DOI:10.1109/memsys.2019.8870889
摘要
We report a vacuum-packaged fused-silica (FS) micro birdbath shell resonator gyroscope (BRG) with near-navigation-grade in-run (evaluation duration day) bias stability of 0.0103 deg/h (at room temperature without temperature stabilization). The BRG utilizes a 5mm diameter birdbath (BB) resonator with n=2 wineglass mode f=10.5436 kHz and original frequency split (Δf)=6 Hz:. The BRG is encapsulated in an LCC package and has an excellent Q (1.54 million) and decay time constant (r=46 s) after near mode matching. The performance is believed to be limited by the noise from readout-and-control circuitry. The bias stability of this device is among the best reported values for micro-scale vibratory gyroscopes today.
科研通智能强力驱动
Strongly Powered by AbleSci AI