谐波
断层(地质)
故障检测与隔离
感应电动机
工程类
转子(电动)
背景(考古学)
谐波分析
电压
状态监测
控制理论(社会学)
计算机科学
电子工程
电气工程
地质学
人工智能
执行机构
地震学
古生物学
控制(管理)
作者
Jorge Bonet-Jara,Joan Pons-Llinares,Konstantinos N. Gyftakis
标识
DOI:10.1109/tie.2022.3231333
摘要
Early detection of interturn faults is one of the most important issues in electrical machines, as the fault severity evolves very fast to a catastrophic failure due to the high thermal stress. However, as this article shows, in submersible induction motors for deep-well pumps, it evolves slower. These motors are highly water-cooled, which significantly reduces the thermal stress caused by the fault, increasing the possibility of early detection. Among fault detection methods, only those based on line current/voltage measurements can be used, as motors are at great depths. This article investigates the principal slot harmonics as reliable indicators for early detection of interturn faults in this application. To this end, a comprehensive analysis is conducted using finite-element analysis where the behavior of these harmonics is studied under different fault severities, both alone and coexisting with other asymmetries, such as unbalanced voltages, eccentricity, or rotor faults. The findings are used to develop a reliable diagnostic scheme based on the monitoring of the most fault-sensitive harmonics along with the voltage and current unbalance indexes. Finally, the scheme is applied, for the first time, in the context of continuous monitoring of a 230-HP induction motor showing its efficacy.
科研通智能强力驱动
Strongly Powered by AbleSci AI