超声波传感器
材料科学
联轴节(管道)
声学
局部放电
复合材料
超声波检测
结构工程
传感器
压力传感器
有限元法
作者
Hong Liu,Zhiqing Shu,Haoyuan Tian,Jianxin Wang,Xuetao Duan,Wentao Zhang,Xuxuan Song,Ziyi Wang,Weigen Chen
出处
期刊:
[Institute of Electrical and Electronics Engineers]
日期:2026-09-01
卷期号:: 1-4
标识
DOI:10.1109/ichve72357.2026.11768459
摘要
To address the need for sensor performance optimization in ultrasonic detection of partial discharges in oil-paper-insulated transformers, this paper investigates the performance differences between Fabry-Pérot ultrasonic sensors with two distinct-coupled structures in partial discharge detection. Through theoretical analysis of the sensing principles of the two coupling mechanisms (direct-coupled and indirect-coupled), sensors with corresponding structures were fabricated, and their frequency response characteristics as well as the time-frequency domain responses of partial discharge signals were compared and tested. The results indicate that the direct-coupled structure possesses a wider frequency response range (1–200 kHz) and a relatively flat response curve, enabling the comprehensive acquisition of broadband acoustic emission signals from partial discharges; in contrast, the indirect-coupled structure exhibits a significant resonance enhancement effect at approximately 57 kHz, demonstrating high sensitivity but pronounced frequency band selectivity. Both structures offer distinct advantages in terms of frequency coverage and detection sensitivity, demonstrating good complementary characteristics.