作者
Huijun Zhang,Shiyu Wang,Yongbing Zhu,Sanping Zhao,Yaguang Nie,Xiaoyong Liao,Hongying Cao,Hao Yin,Xiaodong Liu
摘要
Huijun Zhanga, Shiyu Wanga, Yongbing Zhub*, Sanping Zhaob, Yaguang Niec, Xiaoyong Liaod, Hongying Caod, Hao Yine & Xiaodong Liua*a Anhui Province Key Laboratory of Polar Environment and Global Change, School of Earth and Space Sciences, University of Science and Technology of China, Hefei, Anhui, Chinab State Key Laboratory of NBC Protection for Civilian, Beijing, Chinac Information Materials and Intelligent Sensing Laboratory of Anhui Province, Institutes of Physical Science and Information Technology, Anhui University, Hefei, Chinad Key Laboratory of Land Surface Pattern and Simulation, Institute of Geographic Sciences and Natural Resources Research, Chinese Academy of Sciences, Beijing, Chinae Instruments' Center for Physical Science, University of Science and Technology of China, Hefei, ChinaSupplemental data for this article is available online at https://doi.org/10.1080/00032719.2022.2059495.CONTACT Yongbing Zhu zhuyb16@mail.ustc.edu.cn No.37, Yangfang Central South Street, Changping District, Beijing City, China; Xiaodong Liu ycx@ustc.edu.cn No. 96, Jinzhai Road, Baohe District, Hefei City, Anhui Province, China.AbstractAn analytical method of accelerated solvent extraction combined with gas chromatographic – microelectron capture detection (GC-μECD) was developed for the determination of energetic compounds (ECs) in soils from Chinese ammunition-contaminated sites. The results showed that the recoveries of most compounds were 82.86 ± 7.35 − 109.70 ± 10.82%, 82.53 ± 6.18 − 99.21 ± 1.88%, 80.44 ± 1.73 − 108.20 ± 4.58% at spiked levels of 20, 100, and 500 ng, respectively. Each spiked level was analyzed in triplicate with relative standard deviations from 3.51 to 13.34%, 1.90 to 10.51%, and 0.50 to 5.90%. GC-μECD is highly sensitive to these electronegative compounds with method detection limits (MDL) from 0.64 to 3.48 ng·g−1. This technique has the advantages of high efficiency, reduced solvent consumption, low detection limits, and suitability for a wide range of compounds. The developed approach was successfully applied to the determination of energetic compounds in soils collected from four ammunition-contaminated sites in China. The concentrations of energetic compounds in soil were from 5.60 to 9.22 × 105 ng·g−1 at these sites. The results show that the present method accurately simultaneously determined multiple energetic compounds that may assist with the characterization of soil pollution.