医学
溃疡性结肠炎
结肠镜检查
内科学
胃肠病学
内窥镜检查
活检
炎症性肠病
临床终点
结肠炎
临床试验
疾病
结直肠癌
癌症
作者
K Takenaka,Toshimitsu Fujii,Ami Kawamoto,Kohei Suzuki,Hiromichi Shimizu,Chiaki Maeyashiki,Osamu Yamaji,Maiko Motobayashi,Akira Igarashi,Ryoichi Hanazawa,Shuji Hibiya,Masakazu Nagahori,Eiko Saito,Ryuichi Okamoto,Kazuo Ohtsuka,Mamoru Watanabe
标识
DOI:10.1016/s2468-1253(21)00372-1
摘要
A combination of endoscopic and histological evaluation is important in the management of patients with ulcerative colitis. We aimed to adapt our previous deep neural network system (deep neural ulcerative colitis [DNUC]) to full video colonoscopy and evaluate its validity in the real-time detection of histological mucosal inflammation.In this multicentre, cross-sectional study, we prospectively enrolled consecutive patients (≥15 years) with ulcerative colitis who had an indication for colonoscopy at five hospitals in Japan. Patients in clinical remission were randomly assigned (1:2) to study 1 and study 2. Those with clinically active disease were assigned to study 2 only. Study 1 assessed the validity of real-time histological assessment using DNUC and study 2 validated the consistency of endoscopic scoring between DNUC and experts. The primary endpoint for study 1 was comparison of the results judged by DNUC (healing or active) with biopsy specimens evaluated by pathologists. In study 2, the primary endpoint was the ability of DNUC to determine the Ulcerative Colitis Endoscopic Index of Severity score compared with centrally evaluated scoring by inflammatory bowel disease endoscopy experts.From April 1, 2020, to March 31, 2021, 770 patients (180 in study 1 and 590 in study 2) were enrolled. Using real-time histological evaluation, DNUC was able to evaluate the presence or absence of histological inflammation in 729 (81%) of 900 biopsy specimens. For predicting histological remission, the DNUC had a sensitivity of 97·9% (95% CI 97·0-98·5) and a specificity of 94·6% (91·1-96·9). Moreover, its positive predictive value was 98·6% (97·7-99·2) and negative predictive value was 92·1% (88·7-94·3). The intraclass correlation coefficient between DNUC and experts for endoscopic scoring was 0·927 (95% CI 0·915-0·938).DNUC provided consistently accurate endoscopic scoring and showed potential for reducing the number of biopsies required. This system is an objective and consistent application for video colonoscopy that has potential for use in various medical situations.Tokyo Medical and Dental University and Sony.
科研通智能强力驱动
Strongly Powered by AbleSci AI