屋顶
TRNSYS公司
小气候
光伏系统
零能耗建筑
能量流
光伏
反射面
环境科学
太阳能
传热
气象学
电
土木工程
能量(信号处理)
能源需求
工程类
热的
地理
机械
自然资源经济学
考古
经济
物理
电气工程
统计
曲面(拓扑)
数学
几何学
作者
Vasilis C. Kapsalis,D. Karamanis
标识
DOI:10.1016/j.enbuild.2015.09.016
摘要
Abstract The effect of a building added PV array on building's energy demand is analyzed during different seasons. A methodology based on in house and modified components of TRNSYS is developed by temperatures measurements in a pilot University building in Western Greece. Two roofs, one conventional and one underneath an 9.6 kW polycrystalline PV array system, are explored as part of a detailed building energy system, taking into account the microclimate external flow patterns, the geometry of the canopy architecture and the electricity production. The complex air flow underneath the canopy is also analyzed and its effect on heat transfer revealed. The vertical temperature distribution is validated by measured data at a roof surface of 0.55 absorptance value. In addition to electricity production, applying the simulation results, seasonal heating loads increase of 6.7% and cooling loads decrease of 17.8% are determined, in the top floor, under typical energy management dwelling considerations. The results indicate that the effect of the roof added PV on buildings energy performance should be taken into account for seasonal strategies towards an efficient design and enhanced net zero energy operation.
科研通智能强力驱动
Strongly Powered by AbleSci AI