摘要
Traditional Segmented Gamma Scanning (SGS) and Tomographic Gamma Scanning (TGS) reconstruct activities in low- and intermediate-level radioactive waste drums by assuming radionuclide distributions, which often differ from actual source distributions and lead to inaccurate detection efficiencies and large activity reconstruction errors in practical nondestructive measurement applications. This paper proposes a Compton scattering-based method for direct radioactive-source localization and activity reconstruction in a waste drum with unknown source number and positions. Valid events consisting of one Compton scattering interaction and one photoelectric absorption interaction in the first two layers of a CZT detector were used for source localization, followed by efficiency calculation and activity reconstruction. For single sources emitting 0.662 and 1.333 MeV gamma rays, the localization error was less than 1 cm. For multiple sources, distinguishability depended on source spacing. When the spacing was 6 cm or larger, individual sources were resolved, with localization errors generally below 1 cm. When the spacing was less than 6 cm, multiple sources were reconstructed as one broadened peak; the resulting localization deviations ranged from 1 to 2.3 cm, with a maximum of 2.26 cm. For distinguishable sources, the reconstructed activity error was within ±5%, whereas unresolved multi-source cases showed a maximum error of -15.96%.