作者
L Sawicki,Johannes Grueneisen,Benedikt Michael Schaarschmidt,Christian Buchbender,James Nagarajah,Lale Umutlu,Gerald Antoch,Sonja Kinner
摘要
Objectives To compare the diagnostic performance of 18F-fluordesoxyglucose positron emission tomography/magnetic resonance imaging (18F-FDG PET/MRI) with 18F-FDG PET/computed tomography (18F-FDG PET/CT), MRI, and CT in whole-body staging of recurrent breast cancer. Material and methods Twenty-one consecutive patients (age 59.4 ± 11.5 years, range 38.5–76.9 years; 20 female, 1 male) with suspected breast cancer recurrence underwent a clinically indicated 18F-FDG PET/CT and subsequently a 18F-FDG PET/MRI examination in a single injection protocol (mean injected activity: 257 ± 44 MBq 18F-FDG). Each 18F-FDG PET/MRI, 18F-FDG PET/CT, as well as the CT component of PET/CT (CTPET/CT) and MR images of PET/MRI (MRIPET/MRI) were separately evaluated by two radiologists regarding lesion count, lesion localization, and lesion categorization (benign/malignant). The reference standard was based on histopathological results as well as prior and follow-up imaging. A Wilcoxon test assessed differences in SUVmax between 18F-FDG PET/MRI and 18F-FDG PET/CT. Correlation of SUVmax between 18F-FDG PET/MRI and 18F-FDG PET/CT was calculated using Pearson's correlation coefficient. Interobserver agreement on dignity ratings was evaluated using Cohen's kappa. Results According to the reference standard, 17 patients had breast cancer recurrence. 18F-FDG PET/MRI, 18F-FDG PET/CT, and MRIPET/MRI correctly identified each of the 17 patients, whereas CTPET/CT correctly identified 15 of the 17 patients. A total of 134 lesions were described (116 malignant, 18 benign). 18F-FDG PET/MRI detected all 134 lesions, of which 18F-FDG PET/CT, MRIPET/MRI, and CTPET/CT detected 97.0%, 96.2%, and 74.6%, respectively. 18F-FDG PET/MRI yielded the highest proportion of correctly categorized lesions (98.5%) compared with 18F-FDG PET/CT (94.8%), MRIPET/MRI (88.1%), and CTPET/CT (57.5%). SUVmax was strongly correlated (r = 0.72) but measured significantly higher on 18F-FDG PET/MRI than on 18F-FDG PET/CT in corresponding PET-positive lesions (SUVmax: 5.6 ± 2.8 vs. 4.9 ± 1.8; p = 0.001). Interobserver agreement on lesion dignity was substantial with 18F-FDG PET/MRI (k = 0.65; p< 0.001) and 18F-FDG PET/CT (k = 0.65; p< 0.001). With MRIPET/MRI interobserver analysis yielded a moderate agreement (k = 0.56; p< 0.001), whereas there was only fair agreement evaluating the CTPET/CT datasets (k = 0.31; p = 0.002). Conclusions 18F-FDG PET/MRI offered the highest diagnostic performance compared with 18F-FDG PET/CT, MRI and CT. Thus, 18F-FDG PET/MRI should be regarded as a valuable alternative in whole-body staging of recurrent breast cancer.