交叉研究
医学
胰岛素
基础胰岛素
基础(医学)
2型糖尿病
糖尿病
冲刷
内科学
连续血糖监测
随机对照试验
前瞻性队列研究
变异系数
血糖自我监测
2型糖尿病
内分泌学
血糖性
化学
替代医学
安慰剂
病理
色谱法
作者
Fei Sun,Bin Gao,Aili Yang,Lijun Ren,Ying Xing,Kaiyan Ma,Tian Li,Simin Li,Chunni Heng,Hao Liu,Jie Zhou,Qiuhe Ji
标识
DOI:10.1080/17425247.2022.2147504
摘要
Background Fasting glucose variability (FGV) extensively promotes the onset and development of diabetic complications. This study aimed to evaluate the FGV in type 2 diabetes mellitus (T2DM) patients administered basal insulin using a needle-free insulin injector (NFII).Research design and methods This was a prospective randomized multicenter open-label crossover study. We randomly assigned 48 T2DM patients to receive basal insulin by NFII or conventional insulin pen (CIP) for 7–14 days and were then crossed over after washout. We conducted continuous glucose monitoring to investigate the FGV, our primary outcome was a composite parameter of the FGV with a fasting blood glucose target between 4.4 and 6.1 mmol/L.Results The coefficient of variation for sensor glucose at 6 a.m. with CIP was 11.67 (8.70,14.81)% vs. 9.48 (6.48,12.24)% with NFII (p = 0.003), and the coefficient of variation for mean sensor glucose at 5–6 a.m. with CIP was 12.70 (9.17,16.56)% vs. 9.23 (7.01,11.98)% with NFII (p < 0.001). The overall basal insulin dosage with CIP injection was 18.00 (16.00, 20.00) IU vs. 16.00 (12.00, 19.00) IU during NFII (p < 0.003).Conclusion Compared with CIP, the use of the NFII to inject basal insulin improved FGV in T2DM.Clinical trial registration https://www.chictr.org.cn Identifier is ChiCTR2000034674.
科研通智能强力驱动