Disk Magneto-Cumulative Generator With Explosive Current Opening Switch
作者
V.A. Demidov,A. S. Boriskin,S. A. Kazakov,Е. В. Шаповалов,A. P. Romanov,V. A. Yanenko,Yuri N Lashmanov,Y V Vlasov,S. N. Golosov,S. V. Kutumov,Eugeny I Schetnkov,Natalya R. Kazakova,Sergey E Pavlov,A. A. Agapov,Alexander S. Sevastyanov
The first test of a pulsed power system consisting of a five-element disk magneto-cumulative generator with high-explosive charges of 240 mm diameter and an explosive current opening switch with ribbed barrier was carried out in the frameworks of a program for creating an explosive complex EMIR, intended for the generation of high-power soft X-ray radiation pulses. A current pulse of ~ 9 MA with a characteristic rise time of ~ 0.6 μs was recorded at opening of the generator circuit with the current of ~ 15 MA into a ~ 7 nH inductance load.