As urban subway systems have become a primary mode of transportation, the issue of tunnel fires has garnered significant attention. The presence of piston winds generated by moving trains adds complexity to tunnel fire dynamics. To gain deeper insights into the fire characteristics, 3D dynamic simulations are conducted to explore the moving train fire in tunnel. The influence of fire source heat release rate (HRR), fan pressure, and train speed are studied. Comparative analysis explores smoke removal by vertical shaft and local semi-transverse ventilation. The results show that with the increase of fan pressure, the vertical shaft ventilation is enhanced, and the smoke exhaust layer is reduced from 210 to 125 m. Stopping the train downstream of the vertical shaft allows for better ventilation. Local semi-transverse ventilation is better than vertical shaft ventilation. The train stops below the local semi-transverse segment to achieve the best ventilation effect, but the location of the vent should be considered. This study lays a safety foundation for the development of long tunnels and the establishment of ventilation and smoke exhaust strategies during tunnel fires, providing a basis for the development of larger and longer railway tunnels.