医学
间质性肺病
核医学
放射科
金标准(测试)
前瞻性队列研究
置信区间
高分辨率计算机断层扫描
肺
内科学
作者
Thomas Frauenfelder,Anna Winklehner,Thi Dan Linh Nguyen‐Kim,Rucsandra Dobrotă,Stephan Baumueller,Britta Maurer,Oliver Distler
标识
DOI:10.1136/annrheumdis-2014-205637
摘要
Objectives
Early diagnosis of interstitial lung disease (ILD), currently the main cause of death in systemic sclerosis (SSc), is needed. The gold standard is high-resolution CT (HRCT) of the chest, but regular screening faces the risk of increased radiation exposure. We performed a prospective validation of a dedicated, 9-slice HRCT protocol with reduced radiation dose for the detection of ILD in patients with SSc. Methods
We analysed 170/205 consecutive patients with SSc. Whole-chest HRCT, serving as standard of reference, and the reduced HRCT with nine slices allocated according to a basal–apical gradient were obtained. ILD presence, extent (> or <20%) and diagnostic confidence were assessed. The reduced HRCT was independently analysed by two blinded radiologists, who also evaluated image quality. Radiation dose parameters were calculated. Results
Standard chest HRCT showed ILD in 77/170 patients. With the reduced HRCT, 68/77 cases with ILD were identified (sensitivity 88.3%, both readers). The accuracy (91.8%, reader 1; 94.7%, reader 2), diagnostic confidence (98.8%, reader 1; 95.3%, reader 2) and image quality rates were high. Minimal ILD was correctly quantified in 73.1% (reader 1)/71.2% (reader 2) and extensive ILD in 88% (reader 1)/100% (reader 2). Importantly, the reduced HRCT had a significantly lower radiation dose. The mean dose length product (effective dose) was only 5.66±4.46 mGycm (0.08±0.06 mSv) compared with the standard protocol dose of 149.00±95.90 mGycm (2.09±1.34 mSv). Conclusions
The above-described reduced chest HRCT protocol reliably detects even mild SSc-ILD in clinical practice, with the advantage of a much lower radiation dose compared with standard whole-chest HRCT.