We reviewed the current literature to estimate incidence rates for adverse events with pedicled flaps in the hand. We identified 241 different studies reporting adverse events for 6693 flaps. The average incidence rate was 5.4% and total or partial loss of flap constituted 65% of all reported complications. Flaps with reverse or perforator-based flow may be more prone to vascular complications compared with flaps with antegrade flow or skin pedicle. The incidence rates were acceptable in all flaps (1%-10%) and thus the flap can be chosen primarily based on considerations other than risk of adverse events.