医学
氰基丙烯酸酯
超声波
放射科
静脉曲张
图层(电子)
胶粘剂
有机化学
化学
作者
Alexa Mordhorst,Gary K. Yang,Jerry C. Chen,Shung Lee,Joël Gagnon
出处
期刊:Phlebology
[SAGE Publishing]
日期:2021-05-27
卷期号:36 (9): 752-760
被引量:10
标识
DOI:10.1177/02683555211015564
摘要
Objective The use of cyanoacrylate products (CA) in incompetent perforator vein (IPV) treatment has not been thoroughly examined. The primary objective of this study is to describe the technique of ultra sound guided direct injection of IPV with CA, and secondarily to determine early closure rates and safety of this technique. Methods A retrospective analysis of patients undergoing IPV injection at two centres between 2015-2018 was conducted. Demographics, CEAP classification and IPV location were collected. Outcomes were assessed at two follow-up appointments. Results A total of 83 perforator vein injections were completed. CEAP classifications include C2 – C6 classes. Location of perforators were posteromedial (6%), femoral canal (9%), paratibial (14%), and posterior-tibial (71%). IPV closure rates were 96.3% at initial follow-up (16 ± 2 days). Closure rates decreased to 86.5% at second follow-up (72 ± 9 days). There were no deep vein thromboses during follow-up. One patient developed septic thrombophlebitis that was successfully managed with antibiotics. Conclusion Ultrasound-guided CA glue injection is a simple and low risk procedure that effectively closes incompetent perforator veins.
科研通智能强力驱动
Strongly Powered by AbleSci AI