折射率
光学
谐振器
波长
材料科学
波导管
物理
光电子学
作者
Carlos Angulo Barrios,Kristinn B. Gylfason,Benito Sánchez,Amadeu Griol,Hans Sohlström,Miguel Holgado,Rafael Casquel
出处
期刊:Optics Letters
[The Optical Society]
日期:2007-10-17
卷期号:32 (21): 3080-3080
被引量:366
摘要
We report an experimental demonstration of an integrated biochemical sensor based on a slot-waveguide microring resonator. The microresonator is fabricated on a Si3N4-SiO2 platform and operates at a wavelength of 1.3 microm. The transmission spectrum of the sensor is measured with different ambient refractive indices ranging from n=1.33 to 1.42. A linear shift of the resonant wavelength with increasing ambient refractive index of 212 nm/refractive index units (RIU) is observed. The sensor detects a minimal refractive index variation of 2x10(-4) RIU.