A methodology for image quality evaluation of advanced CT systems

作者
Joshua M. Wilson,Olav I. Christianson,Samuel Richard,Ehsan Samei
出处
期刊:Medical Physics [Wiley]
卷期号:40 (3): 031908-031908 被引量:105
标识
DOI:10.1118/1.4791645
摘要

PURPOSE: This work involved the development of a phantom-based method to quantify the performance of tube current modulation and iterative reconstruction in modern computed tomography (CT) systems. The quantification included resolution, HU accuracy, noise, and noise texture accounting for the impact of contrast, prescribed dose, reconstruction algorithm, and body size. METHODS: A 42-cm-long, 22.5-kg polyethylene phantom was designed to model four body sizes. Each size was represented by a uniform section, for the measurement of the noise-power spectrum (NPS), and a feature section containing various rods, for the measurement of HU and the task-based modulation transfer function (TTF). The phantom was scanned on a clinical CT system (GE, 750HD) using a range of tube current modulation settings (NI levels) and reconstruction methods (FBP and ASIR30). An image quality analysis program was developed to process the phantom data to calculate the targeted image quality metrics as a function of contrast, prescribed dose, and body size. RESULTS: The phantom fabrication closely followed the design specifications. In terms of tube current modulation, the tube current and resulting image noise varied as a function of phantom size as expected based on the manufacturer specification: From the 16- to 37-cm section, the HU contrast for each rod was inversely related to phantom size, and noise was relatively constant (<5% change). With iterative reconstruction, the TTF exhibited a contrast dependency with better performance for higher contrast objects. At low noise levels, TTFs of iterative reconstruction were better than those of FBP, but at higher noise, that superiority was not maintained at all contrast levels. Relative to FBP, the NPS of iterative reconstruction exhibited an ~30% decrease in magnitude and a 0.1 mm(-1) shift in the peak frequency. CONCLUSIONS: Phantom and image quality analysis software were created for assessing CT image quality over a range of contrasts, doses, and body sizes. The testing platform enabled robust NPS, TTF, HU, and pixel noise measurements as a function of body size capable of characterizing the performance of reconstruction algorithms and tube current modulation techniques.
最长约 10秒,即可获得该文献文件

科研通智能强力驱动
Strongly Powered by AbleSci AI
科研通是完全免费的文献互助平台,具备全网最快的应助速度,最高的求助完成率。 对每一个文献求助,科研通都将尽心尽力,给求助人一个满意的交代。
实时播报
柚子完成签到,获得积分10
刚刚
你好发布了新的文献求助10
刚刚
Anonymous完成签到,获得积分0
刚刚
坚定蘑菇发布了新的文献求助80
1秒前
Owen的应助被小许采纳,获得10
1秒前
意君兮完成签到,获得积分10
1秒前
鲁世键发布了新的文献求助10
1秒前
小白发布了新的文献求助10
1秒前
辣白菜发布了新的文献求助30
2秒前
美味的冷面完成签到,获得积分10
2秒前
皮皮虾完成签到 ,获得积分10
2秒前
jerseyxin发布了新的文献求助10
2秒前
甄东发布了新的文献求助10
2秒前
闪闪闪关注了科研通微信公众号
3秒前
3秒前
上官若男的应助被01采纳,获得10
3秒前
3秒前
852的应助被poet泸沽采纳,获得10
3秒前
3秒前
大个的应助被淡然幻波采纳,获得10
3秒前
www发布了新的文献求助10
4秒前
干净的洋葱完成签到,获得积分10
4秒前
隐形曼青的应助被qieshuidao采纳,获得30
5秒前
5秒前
神勇的晓啸完成签到,获得积分10
5秒前
文艺书琴完成签到,获得积分10
5秒前
6秒前
JYJ的应助被yuiiuy采纳,获得10
6秒前
6秒前
rachel03发布了新的文献求助10
6秒前
DD关闭了DD的文献求助
6秒前
6秒前
天真的一斩完成签到,获得积分10
7秒前
7秒前
Ava的应助被冷静勒采纳,获得10
7秒前
季禾完成签到,获得积分10
8秒前
molihuakai的应助被皮皮虾采纳,获得10
8秒前
8秒前
FXL完成签到,获得积分20
8秒前
9秒前
高分求助中
(应助此贴封号)【重要!!请各用户(尤其是新用户)详细阅读】【科研通的精品贴汇总】 10000
Aspects of Post-SPE Phonology 2000
Recombinant human Type III collagen with native-like assembly and real biomaterial performance 1000
Children in Mind: Their mental health in today’s world and what we can do to help them 900
Performance standards for antimicrobial disk and dilution susceptibility tests for bacteria isolated from animals 888
Rosenblum, Global Change Biology 800
Holistic Discourse Analysis, Second Edition by Robert E. Longacre (2012-09-10) 666
热门求助领域 (近24小时)
化学 材料科学 医学 生物 计算机科学 工程类 纳米技术 物理 有机化学 化学工程 内科学 生物化学 复合材料 催化作用 心理学 细胞生物学 无机化学 电极 光电子学 人工智能
热门帖子
关注 科研通微信公众号,转发送积分 7875230
求助须知:如何正确求助?哪些是违规求助? 9390820
关于积分的说明 20784208
捐赠科研通 7476839
什么是DOI,文献DOI怎么找? 3352487
关于科研通互助平台的介绍 2492968
邀请新用户注册赠送积分活动 2379243