摘要
OBJECTIVE: Accurate measurement of thyroglobulin (Tg) is crucial for managing patients with differentiated thyroid cancer (DTC). This study aims to verify the analytical performance of the Abbott Tg assay and establish Tg reference intervals in an apparently healthy Chinese population. METHODS: Analytical performance was evaluated in terms of precision, detection capabilities, and linearity. A method comparison with the Roche Tg assay was conducted using Passing-Bablok regression and Bland-Altman analysis. Reference intervals were established using serum Tg levels measured by the Abbott Alinity system in 1,081 healthy volunteers, categorized by age and gender. RESULTS: =0.008). CONCLUSION: The Abbott Tg assay demonstrates verified analytical performance as per the manufacturer's claims. Reference intervals were established for an apparently healthy Chinese population, highlighting the significant influence of age on serum Tg levels.