磁导率
材料科学
无损检测
复合材料
医学
化学
放射科
膜
生物化学
作者
Kwon-Sang Ryu,Yun-Hee Lee,Jong-Seo Park,Un-Bong Baek
标识
DOI:10.4283/jmag.2012.17.3.206
摘要
Peak interval for reversible permeability is presented for nondestructively evaluating the remanent life of 1Cr-0.5Mo steel. The method to measure the peak interval of reversible permeability is based on the value of reversible permeability is the same as the differential value of the hysteresis loop. The measurement principle is based on the first harmonics voltage induced in a sensing coil using a lock-in amplifier tuned to a frequency of the exciting voltage. Results obtained for the peak interval of reversible permeability and Rockwell hardness on the aged samples decrease as aging time and the Larson-Miller parameter increase. We could estimate the remanent life of 1Cr-0.5Mo steel by using the relationship between the peak interval of reversible permeability and the Larson-Miller parameter, nondestructively.
科研通智能强力驱动
Strongly Powered by AbleSci AI