过调制
谐波
控制理论(社会学)
调制指数
总谐波失真
子空间拓扑
谐波
逆变器
感应电动机
谐波分析
失真(音乐)
电压
数学
计算机科学
物理
声学
人工智能
数学分析
电信
量子力学
控制(管理)
带宽(计算)
放大器
作者
Li Zhao,Shoudao Huang,Jian Zheng,Yuan Gao
出处
期刊:Energies
[Multidisciplinary Digital Publishing Institute]
日期:2022-10-14
卷期号:15 (20): 7589-7589
被引量:3
摘要
For the asymmetric six-phase motor fed by a two-level six-phase voltage source inverter (VSI), when the modulation index is less than 0.5774, the motor operates in the linear region, and the harmonics in the Z1 − Z2 subspace can be suppressed to zero. When the modulation index is beyond 0.5774 and less than 0.6221, the motor operates in overmodulation regions, and the harmonics in the Z1 − Z2 subspace cannot be suppressed to zero. To minimize the harmonics in the Z1 − Z2 subspace for these regions, a harmonic suppression strategy, namely, harmonic suppression overmodulation strategy (HSOS), is proposed in this paper. The lower-order harmonics of the Z1 − Z2 subspace, namely, the 5th, 7th, 17th and 19th, are considered. Compared with the traditional four-vector overmodulation strategy (TFOS), the content of the 5th harmonic is reduced by about 20%, and the total harmonic distortion (THDZ1Z2) of these four kinds of harmonics is reduced by about 21% in the proposed HSOS. Finally, the simulation and experiment are carried out to verify the effectiveness of the proposed strategy.
科研通智能强力驱动
Strongly Powered by AbleSci AI