已入深夜,您辛苦了!由于当前在线用户较少,发布求助请尽量完整地填写文献信息,科研通机器人24小时在线,伴您度过漫漫科研夜!祝你早点完成任务,早点休息,好梦!

The Future in Perforator Flap Imaging: A New Technique to Substantially Reduce Radiation Dose with Computed Tomographic Angiography

作者
Warren M. Rozen,Daniel Chubb,Marcus Peter Crossett,Mark W. Ashton
出处
期刊:Plastic and Reconstructive Surgery [Lippincott Williams & Wilkins]
卷期号:126 (2): 98e-100e 被引量:14
标识
DOI:10.1097/prs.0b013e3181de25f9
摘要

Sir: The use of preoperative imaging in perforator flap surgery has been a recent advance that has been shown to improve a range of operative outcome measures.1 In deep inferior epigastric artery perforator flap surgery, flap survival, donor-site morbidity, and length of operation have all been shown to be significantly reduced with the use of preoperative computed tomographic angiography. The use of computed tomographic angiography has thus been incorporated as routine in many centers internationally. Despite these clear benefits of its use, hesitation still exists toward its inherent association with ionizing radiation. Several techniques have recently been described in a move to minimize this radiation exposure. Changes in scanning protocols have achieved substantial dose reduction, with initial scanning techniques using scanning protocols similar to computed tomographic angiography of the abdomen for intraabdominal abnormalities, with calculated radiation doses of up to 10 mSv being received.2 By modifying the protocols specifically for flap planning, the radiation dose of computed tomographic angiography was able to be reduced by 40 percent to 6 mSv.3 To eliminate this exposure completely, the use of magnetic resonance angiography has been investigated; however, descriptions of its use do not yet match those of computed tomographic angiography, and certainly no outcome studies have been reported.4,5 Given that computed tomographic angiography is thus still considered the standard means of preoperative imaging, we describe a recent advance in computed tomographic angiography thus substantially reduces the radiation exposure with its use. Although the use of multidetector row computed tomography scanners has been a great advance in imaging technologies, all previously reported scanners used for perforator imaging have required movement of the computed tomography scanning table to achieve the multiple slices that the computed tomographic scanner acquires (four-slice, 16-slice, and 64-slice multidetector rows). This movement involves some time delay. The capture of multiple slices with these scanners also requires some overlap between adjacent slices. A new advance in computed tomography hardware is the 320-slice multidetector row computed tomographic angiography scanner. This scanner enables 320 data sets to be acquired simultaneously in a single-image “volume” capture, eliminating the need for table movement or multiple slices. These both serve to substantially reduce radiation exposure to the patient. In our experience with the 320 multidetector row computed tomography scanner (Aquilion One; Toshiba America Medical Systems, Tustin, Calif.), we have been able to achieve perforator imaging of the same resolution and quality as previously reported, and with axial slices of 0.5 mm (compared with 0.63 mm with 64-slice scanners), the resolution of three-dimensional reconstructions may in fact be enhanced (Fig. 1). In performing this new technique of “single-volume acquisition” scanning, the radiation dose is substantially reduced to 1.78 mSV. This is equivalent to the radiation dose of approximately three plain abdominal radiographs.2Fig. 1.: (Above) Preoperative computed tomographic angiography, volume-rendered reconstruction of the abdominal wall vasculature, using a 320-slice multidetector row computed tomography scanner (Aquilion One, Toshiba, Calif.), highlighting a single, large, 1.5-mm perforator (blue arrow). (Center) Grid based at the umbilicus applied for localization. (Below) Maximum intensity projection view of perforators relative to the deep inferior epigastric arteries.Since the first reports of computed tomographic angiography for perforator imaging only 3 years ago, there has been a revolution in advanced imaging technologies for perforator flap imaging. With ongoing research, these techniques have continued to become safer and provide growing levels of anatomical detail. Through increasing patient accessibility to imaging technologies, ongoing validation of the benefits from the use of these tools will be increasingly available. DISCLOSURE The authors have no financial interest to declare in relation to the content of this article. Warren M. Rozen, M.B.B.S., B.Med.Sc., Ph.D. Daniel Chubb, M.B.B.S., B.Med.Sc. Jack Brockhoff Reconstructive Plastic Surgery Research Unit University of Melbourne Parkville, Victoria, Australia Marcus Crossett, Ba.App.Ph. Monash Heart Department of Radiology Monash Medical Center Clayton, Victoria, Australia Mark W. Ashton, M.B.B.S., M.D. Jack Brockhoff Reconstructive Plastic Surgery Research Unit University of Melbourne Parkville, Victoria, Australia

科研通智能强力驱动
Strongly Powered by AbleSci AI
科研通是完全免费的文献互助平台,具备全网最快的应助速度,最高的求助完成率。 对每一个文献求助,科研通都将尽心尽力,给求助人一个满意的交代。
实时播报
泠泠晚禾完成签到 ,获得积分10
刚刚
Joji发布了新的文献求助10
1秒前
3秒前
曾hf完成签到 ,获得积分10
4秒前
TT完成签到,获得积分10
5秒前
TTTTTT完成签到,获得积分10
5秒前
6秒前
7秒前
马浩航发布了新的文献求助30
7秒前
xianghp的应助被科研通管家采纳,获得10
7秒前
CipherSage的应助被科研通管家采纳,获得10
7秒前
丘比特的应助被科研通管家采纳,获得10
7秒前
7秒前
阿巴阿巴完成签到 ,获得积分10
8秒前
8秒前
哲000完成签到 ,获得积分10
11秒前
小凯完成签到 ,获得积分10
11秒前
王智发布了新的文献求助10
12秒前
是羊羊吖完成签到 ,获得积分10
12秒前
liu311完成签到,获得积分10
12秒前
吉吉国王发布了新的文献求助10
13秒前
14秒前
14秒前
16秒前
车车完成签到,获得积分20
16秒前
RRRenaissance完成签到,获得积分10
17秒前
丘比特的应助被卢博成采纳,获得10
18秒前
18秒前
18秒前
结实大白完成签到,获得积分10
18秒前
刀客特幽发布了新的文献求助10
18秒前
20秒前
bkagyin的应助被研究生小白采纳,获得10
20秒前
21秒前
Juli完成签到,获得积分10
22秒前
22秒前
Perpetual完成签到 ,获得积分10
23秒前
郭子仪发布了新的文献求助10
23秒前
大能发布了新的文献求助10
23秒前
tao完成签到 ,获得积分10
23秒前
高分求助中
(应助此贴封号)【重要!!请各用户(尤其是新用户)详细阅读】【科研通的精品贴汇总】 10000
Les Mantodea De Guyane 2000
内視鏡下経鼻経蝶形骨洞手術術後SIADHに対する予防的水制限の安全性と有効性の検討 1000
Problems and Solutions for Integer and Combinatorial Optimization: Building Skills in Discrete Optimization 600
Organizational Behavior 510
桑白皮エキスの実験的, 臨床的育毛効果について 500
Nonlinear vehicle active suspension system control method based on the extended high gain observer 500
热门求助领域 (近24小时)
化学 材料科学 医学 生物 纳米技术 计算机科学 工程类 有机化学 化学工程 生物化学 物理 复合材料 内科学 催化作用 光电子学 人工智能 细胞生物学 无机化学 物理化学 数学
热门帖子
关注 科研通微信公众号,转发送积分 8002117
求助须知:如何正确求助?哪些是违规求助? 9454563
关于积分的说明 21150092
捐赠科研通 7574709
什么是DOI,文献DOI怎么找? 3381493
关于科研通互助平台的介绍 2514295
邀请新用户注册赠送积分活动 2415826