Decisions on positioning of monitoring wells in the vicinity of hazardous waste sites can be significantly affected by knowledge of the natural anisotropic hydraulic conductivity. That the vertical permeability is usually less than the horizontal permeability is well known: however, the anisotrophy in the horizontal plane may influence the choice of positions for those monitoring wells that are downgradient from the waste-management area. Very little information on the horizontal anisotropy is available. Furthermore, field measurements to estimate the horizontal anisotropy are expensive because at least three interacting wells are necessary, with more than three being preferred. The Kozeny equation suggests that directional anisotropy of the electrical conductivity of a porous media should correlate closely with the anisotropy of the permeability [S. J. Pirson, Geological Well Log Analysis (Gulk Publ. Co., 1981), p. 135]. A close relationship should also exist between the acoustic anisotropy and the anisotropy of the permeability. Recent advances in techniques for measuring acoustic velocities in a borehole make it feasible to obtain estimates of the anisotropy of the permeability from observations of the anistropy of the seismic velocities. [Work supported by EPA.]