假关节
医学
切断
射线照相术
颈椎前路椎间盘切除融合术
核医学
外科
放射科
物理
颈椎
量子力学
作者
Eaman Balouch,Aonnicha Burapachaisri,Dainn Woo,Zoe Norris,Anand Segar,Ethan W. Ayres,Dennis Vasquez-Montes,Aaron J. Buckland,Afshin E. Razi,Michael L. Smith,Themistocles S. Protopsaltis,Yong H. Kim
出处
期刊:Spine
[Lippincott Williams & Wilkins]
日期:2022-07-14
卷期号:47 (16): 1151-1156
被引量:6
标识
DOI:10.1097/brs.0000000000004375
摘要
STUDY DESIGN: A retrospective review of operative patients at a single institution. OBJECTIVE: The aim was to validate a novel method of detecting pseudarthrosis on dynamic radiographs. SUMMARY OF BACKGROUND DATA: A common complication after anterior cervical discectomy and fusion is pseudarthrosis. A previously published method for detecting pseudarthrosis identifies a 1 mm difference in interspinous motion (ISM), which requires calibration of images and relies on anatomic landmarks difficult to visualize. An alternative is to use angles between spinous processes, which does not require calibration and relies on more visible landmarks. MATERIALS AND METHODS: ISM was measured on dynamic radiographs using the previously published linear method and new angular method. Angles were defined by lines from screw heads to dorsal points of spinous processes. Angular cutoff for fusion was calculated using a regression equation correlating linear and angular measures, based on the 1 mm linear cutoff. Pseudarthrosis was assessed with both cutoffs. Sensitivity, specificity, inter-reliability and intrareliability of angular and linear measures used postoperative computed tomography (CT) as the reference. RESULTS: A total of 242 fused levels (81 allograft, 84 polyetheretherketone, 40 titanium, 37 standalone cages) were measured in 143 patients (mean age 52.0±11.5, 42%F). 36 patients (66 levels) had 1-year postoperative CTs; 13 patients (13 levels) had confirmed pseudarthrosis. Linear and angular measurements closely correlated ( R =0.872), with 2.3° corresponding to 1 mm linear ISM. Potential pseudarthroses was found in 28.0% and 18.5% levels using linear and angular cutoffs, respectively. Linear cutoff had 85% sensitivity, 87% specificity; angular cutoff had 85% sensitivity, 96% specificity for detecting CT-validated pseudarthrosis. Interclass correlation coefficients were 0.974 and 0.986 (both P <0.001); intrarater reliability averaged 0.953 and 0.974 ( P <0.001 for all) for linear and angular methods, respectively. CONCLUSIONS: The angular measure for assessing potential pseudarthrosis is as sensitive as and more specific than published linear methods, has high interobserver reliability, and can be used without image calibration. LEVEL OF EVIDENCE: 3.
科研通智能强力驱动
Strongly Powered by AbleSci AI