医学
痰
肺结核
肺结核
诊断试验
结核分枝杆菌
可用性
置信区间
内科学
诊断准确性
人类免疫缺陷病毒(HIV)
结核病诊断
病毒学
免疫学
病理
作者
Seda Yerlikaya,Masuzyo Chirwa,Bukola Ajide,Maria Del Mar Castro,Huy Ha,Midori Kato‐Maeda,Esther Kisakye,Danaida Marcelo,Tessa Mochizuki,Loren Rockman,Amy Steadman,Balamugesh Thangakunam,John Bimba,D. John Christopher,Monde Muyoyeta,Ha Phan,G. Theron,Charles Yu,Kristin Kremer,Patrick P J Phillips
出处
期刊:PubMed
[National Institutes of Health]
日期:2026-04-30
卷期号:394 (17): 1710-1722
标识
DOI:10.1056/nejmoa2509761
摘要
BACKGROUND: Improved diagnostic tools for tuberculosis that are suitable for use in peripheral health centers are essential for reducing the persistent gap between estimated and notified cases. The diagnostic accuracy and usability of the MiniDock MTB test for detecting pulmonary tuberculosis is unknown. METHODS: We conducted a prospective, cross-sectional study at outpatient centers in India, Nigeria, the Philippines, South Africa, Uganda, Vietnam, and Zambia. Patients 12 years of age or older with presumptive pulmonary tuberculosis were enrolled between September 12, 2024, and March 31, 2025. Assessment with MiniDock MTB was performed with sputum swabs and tongue swabs. Diagnostic accuracy was evaluated against a sputum-culture-based reference and as compared with sputum-smear microscopy and Xpert MTB/RIF Ultra assay. Usability was assessed with a system usability scale and direct observation. RESULTS: A total of 1380 participants were enrolled; 255 (18.5%) had human immunodeficiency virus infection and 226 (16.4%) had culture-confirmed tuberculosis. MiniDock MTB sensitivity was 85.7% (95% confidence interval [CI], 80.4 to 90.0) with sputum and 79.6% (95% CI, 73.8 to 84.7) with tongue swabs; specificity was greater than 97.5% for both. Results of sputum tests with MiniDock MTB closely matched those with Xpert MTB/RIF Ultra for sensitivity (difference, -2.8 percentage points; 95% CI, -6.0 to 0.5). MiniDock MTB had greater sensitivity than smear microscopy for tests of sputum (difference, 24.3 percentage points; 95% CI, 17.9 to 30.7) and tongue swabs (difference, 18.3 percentage points; 95% CI, 12.0 to 24.7). The test showed diagnostic accuracy that was consistent with World Health Organization (WHO) accuracy targets for near-point-of-care tuberculosis diagnostics (≥85% sensitivity for sputum and ≥75% for nonsputum and ≥98% specificity for both). The median score on the system usability scale (range, 0 to 100, with higher scores indicating better perceived usability) was 75 (interquartile range, 65 to 80), which indicated good usability. No adverse events related to the index test were reported. CONCLUSIONS: MiniDock MTB met WHO targets for diagnostic accuracy and usability for tuberculosis detection across diverse clinical settings. (Funded by the National Institutes of Health and others; Rapid Research in Diagnostics Development for TB Network and Assessing Diagnostics at Point-of-Care for Tuberculosis ClinicalTrials.gov numbers, NCT04923958 and NCT05941052.).