医学
急诊分诊台
接收机工作特性
血管造影
改良兰金量表
放射科
冲程(发动机)
等级间信度
置信区间
计算机断层血管造影
缺血性中风
缺血
内科学
评定量表
急诊医学
发展心理学
工程类
机械工程
心理学
作者
Bijoy K. Menon,Christopher D. d’Esterre,Emmad Qazi,Mohammed Almekhlafi,L.J. Hahn,Andrew M. Demchuk,Mayank Goyal
出处
期刊:Radiology
[Radiological Society of North America]
日期:2015-01-29
卷期号:275 (2): 510-520
被引量:603
标识
DOI:10.1148/radiol.15142256
摘要
To describe the use of an imaging selection tool, multiphase computed tomographic (CT) angiography, in patients with acute ischemic stroke (AIS) and to demonstrate its interrater reliability and ability to help determine clinical outcome.The local ethics board approved this study. Data are from the pilot phase of PRoveIT, a prospective observational study analyzing utility of multimodal imaging in the triage of patients with AIS. Patients underwent baseline unenhanced CT, single-phase CT angiography of the head and neck, multiphase CT angiography, and perfusion CT. Multiphase CT angiography generates time-resolved images of pial arteries. Pial arterial filling was scored on a six-point ordinal scale, and interrater reliability was tested. Clinical outcomes included a 50% or greater decrease in National Institutes of Health Stroke Scale (NIHSS) over 24 hours and 90-day modified Rankin Scale (mRS) score of 0-2. The ability to predict clinical outcomes was compared between single-phase CT angiography, multiphase CT angiography, and perfusion CT by using receiver operating curve analysis, Akaike information criterion (AIC), and Bayesian information criterion (BIC).A total of 147 patients were included. Interrater reliability for multiphase CT angiography is excellent (n = 30, κ = 0.81, P < .001). At receiver operating characteristic curve analysis, the ability to predict clinical outcome is modest (C statistic = 0.56, 95% confidence interval [CI]: 0.52, 0.63 for ≥50% decrease in NIHSS over 24 hours; C statistic = 0.6, 95% CI: 0.53, 0.68 for 90-day mRS score of 0-2) but better than that of models using single-phase CT angiography and perfusion CT (P < .05 overall). With AIC and BIC, models that use multiphase CT angiography are better than models that use single-phase CT angiography and perfusion CT for a decrease of 50% or more in NIHSS over 24 hours (AIC = 166, BIC = 171.7; values were lowest for multiphase CT angiography) and a 90-day mRS score of 0-2 (AIC = 132.1, BIC = 137.4; values were lowest for multiphase CT angiography).Multiphase CT angiography is a reliable tool for imaging selection in patients with AIS.
科研通智能强力驱动
Strongly Powered by AbleSci AI